VENT PIPE INLET COLLAR CONVERSION
1. Remove the plug from rear inlet port by unfastening the 6 nuts that secure it to the Plenum. Keep the plug & nuts for later use.
2. Remove the sensing tube from the Fan Proving Switch by loosening the plastic compression fitting.
3. Remove the vent pipe inlet collar from the bottom port by unfastening the 6 nuts that secure it to the plenum. Keep the nuts for
later use.
4. Using a tube cutter, cut the sensing tube 2" from the elbow directed at the vent pipe inlet collar, (See Diagram L). Discard
the cut off section of metal tube.
5. Attach the vent pipe inlet collar to the rear inlet port making sure that the sensing tube is orientated as shown, (See Diagram M).
NOTE: Alignment marks on the inlet collar and plenum casing must match.
6. Attach 90
0
compression fitting to the short tube on the inlet collar.
7. Using the "soft" aluminum tubing, connect the Fan Proving Switch to the inlet collar. Take care not to crimp the tubing.
8. Install the plug removed in step 1 over the bottom inlet port, tightening securely.
VENT PIPE CLAMP ASSEMBLY
1. Attach the three vent pipe clamps to the inlet collar, (See Diagram N).
NOTE: The following diagrams show the use of the rear inlet. The same steps will apply if using the bottom inlet.
2. Bend each vent pipe clamp so it conforms to the outside diameter of the vent pipe being used, (See Diagram O)
3. Route the adjustable clamp through the openings at the opposite end of the legs.
4. Slide the vent pipe over the inlet collar of the SS1-R.
5. Tighten the adjustable clamp around the vent pipe, (See Diagram O).
11
DIAGRAM L
DIAGRAM M
DIAGRAM N
DIAGRAM O