Rev. A 11/11 Copyright © 2011, Tjernlund Products, Inc. All rights reserved. P/N 8504140
NOTE:
The VP-2F and VP-3F Water Heater Vent Packages use a Linear Limit for the safety
interlock circuit. If the pilot light is extinguished, follow the steps under “IN THE EVENT
OF A PILOT OUTAGE” on page 1 of these instructions to relight water heater.
OWNER’S INSTRUCTIONS
THESE INSTRUCTIONS MUST REMAIN
WITH EQUIPMENT
DO NOT DESTROY
ALWAYS FOLLOW WATER
HEATER MANUFACTURER’S
INSTRUCTIONS FOR PROPER
OPERATION OF HEATER AND
RE-LIGHTING OF PILOT
WATER HEATER VENT PACKAGE
For Natural Gas or LP
MODELS
VP-2F For Millivolt Water Heaters up
to 60,000 BTU/hr
VP-3F For Millivolt Water Heaters from
60,000 to 120,000 BTU/hr
Patented
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
Seitenansicht 0
1 2 3 4 5 6 ... 14 15

Inhaltsverzeichnis

Seite 1 - WATER HEATER VENT PACKAGE

Rev. A 11/11 Copyright © 2011, Tjernlund Products, Inc. All rights reserved. P/N 8504140NOTE: The VP-2F and VP-3F Water Heater Vent Packages use a Li

Seite 2

VP-2F / VP-3F WATER HEATER VENT PACKAGE LADDER WIRING DIAGRAMCOMBUSTION AIR TESTWARNING:The Linear Limit spillage sensing switch is designed to alert

Seite 3 - SEQUENCE OF OPERATION

PERFORMANCE CURVES10VP-2F PERFORMANCE CURVEVP-3F PERFORMANCE CURVE

Seite 4

VP-2F / VP-3F TROUBLESHOOTING GUIDE11Note: For further assistance contactSolutionStep 6SolutionStep 5SolutionStep 4SolutionStep 3Step 2Step 1Symptom 1

Seite 5 - DIAGRAM B1

12Note: For further assistance contactStep 3.2Step 6Step 3.1Step 5SolutionStep 4SolutionStep 3Step 2Step 1Symptom 2at 1-800-255-4208, 7:30 - 4:30 CST.

Seite 6 - DIAGRAM C

MAINTENANCE1. The VP-2F & VP-3F motors are permanently lubricated and do not need to be oiled.2. The owner must semiannually inspect the vent hood

Seite 7 - TAPERED REDUCER

VENT HOOD MOUNTING TEMPLATE FOR VP-2F & VP-3F1. Use scissors to detach template. Verify “Vent Hood Installation Clearances” on page 5 are adhered

Seite 8 - VP-2F MOUNTING VP-3F MOUNTING

Tjernlund Products welcomes your comments and questions. Address all correspondence to: Customer Service, Tjernlund Products Inc., 1601 Ninth Street,

Seite 9 - DIAGRAM D

INSTALLER NOTES1. The installer must read and follow these instructions carefully to assure proper installation and operation of the water heater vent

Seite 10 - FIGURE 8075002

3INSTALLATION RESTRICTIONSThe Power Venter shall not be installed on incinerators, condensing type appliances or solid-fuel burning appliances. The Po

Seite 11 - VP-3F PERFORMANCE CURVE

47. Use the 1/4" tubing to connect gas pressure switch fitting to the PRESSURE TAP PORT fitting on the thermostat/gas control valve.8. Conduct a

Seite 12 - FIGURE 8079001 6-7-07

THERMOCOUPLE JUNCTION ADAPTER INSTALLATIONUnscrew thermocouple from gas valve and screw in Thermocouple Junction Adapter.Screw thermocouple into Th

Seite 13 - 8079002 7-18-07

VENT HOOD INSTALLATION1. Verify that proposed Vent Hood location will conform to “Vent Hood Termination Clearances” on page 5.2. Use scissors to deta

Seite 14

MOUNTING POWER VENTER1. To facilitate installation and reduce vibration, we have included 2 mounting brackets, 2 rubber isolators and 2 rubber grommet

Seite 15 - VH1-4 ROUGH-IN 8” Sq

ACTUATING AND SAFETY CONTROL CIRCUIT CONNECTIONS1. If not previously completed, push both leads from the Linear Limit spill switch onto Thermocouple J

Kommentare zu diesen Handbüchern

Keine Kommentare